Comment: typos


Warning

Nerver Never leave LiPo Batteries unattended during charging due to fire hazard.

...

The following instructions should be followed to properly charge the CPM Lab Vehicle LiPo Batteries using a VOLTCRAFT V-CHARGE 50 charger. If unsure, please consult following people for help:

  • Maximilian Kloock
  • Patrick Scheffe

Instructions can also be found in git:


Info
titleGeneral Info
  1. Charge process can be terminated at any point. LiPo Batteries should never be left unattended while charging. Charge should be terminated before before leaving CPM Lab.
  2. LiPo Battery Health and Lifespan is kept highest if LiPo Batteries are regularly charged. Do not hesitate to charge vehicles before battery protection circuit is triggered. The battery protection circuit is triggered at 6.0-6.4V. If possible, charge batteries regularly to maintain a charge between 7.4-8.0V.

1. Charger Setup

Plug charger cable into correct ports.

Image RemovedImage Added

2. Connect Vehicle

Turn off the vehicle (switch should be inboard toward center of vehicle) and connect DSUB connector.

Image Added

Image Added

Turning off the vehicle is important so that charge termination is succesfulsuccessful. LiPo chargers work by charging in two modes, first constant current (CC) then constant voltage (CV). During CV, the current is monitored until it drops under a certain threshold at which point the charger terminates the charging process. If the verhicle vehicle is left on, this threshold current may not be reached and the charger will charge indefinitely.

...

Image Courtesy: https://www.digikey.com/en/articles/techzone/2016/sep/a-designer-guide-fast-lithium-ion-battery-charging

...

3. Charge Vehicle

Info

It is okay to stop LiPo charging at any time if need be e.g. to leave room. To stop charging, press STOP button.

...

SettingLiPo Balance
Charge Current3A
Voltage

2.7V(2S)

...


Image Added


Warning

Never leave LiPo Batteries unattended during charging due to fire hazard.