Nerver leave LiPo Batteries unattended during charging due to fire hazard.


The following instructions should be followed to properly charge the CPM Lab Vehicle LiPo Batteries. If unsure, please consult following people for help:

  • Maximilian Kloock
  • Patrick Scheffe

1. Charger Setup

Plug charger cable into correct ports

2. Connect Vehicle

Turn off the vehicle (switch should be inboard toward center of vehicle) and connect DSUB connector

Turning off the vehicle is important so that charge termination is succesful. LiPo chargers work by charging in two modes, first constant current (CC) then constant voltage (CV). During CV, the current is monitored until it drops under a certain threshold at which point the charger terminates the charging process. If the verhicle is left on, this threshold current may not be reached and the charger will charge indefinitely.

Image Courtesy: https://www.digikey.com/en/articles/techzone/2016/sep/a-designer-guide-fast-lithium-ion-battery-charging

3. Charge Vehicle

It is okay to stop LiPo charging at any time if need be e.g. to leave room. To stop charging, press STOP button.

Follow slide to properly begin charging vehicle. Following settings should be observed:

SettingLiPo Balance
Charge Current3A
Voltage

2.7V(2S)